Connect in 15 seconds

Connect your logger to the GoCluster DX cluster.

GoCluster is a standard telnet DX cluster, so anything that talks to DX Spider, AR-Cluster or CC Cluster can talk to it. Here is the address, the first commands and logger-by-logger guides.

No logger? The web console is the easiest way to start: open ui.n2wq.com in any browser and type your callsign.

LIVE NODEcluster.n2wq.com:8300

Last updated · by N2WQ

Hostcluster.n2wq.com
Port8300
LoginYour callsign
CostFree

How do I connect with plain telnet?

Any computer with a telnet client can connect in seconds. New to telnet, or need to switch it on in Windows? Follow the step-by-step telnet guide. Otherwise, enter one command per line:

telnet cluster.n2wq.com 8300
# log in with your callsign (e.g. W1AW or W1AW-1), then:
HELP   # short help menu
SHOW DX 10   # up to 10 recent spots that pass your filters
SET GRID FN31PR   # your 4- or 6-character Maidenhead grid
SET NOISE SUBURBAN   # QUIET | RURAL | SUBURBAN | URBAN | INDUSTRIAL
SHOW FILTER   # see your filters (pauses live spots)
RESUME   # continue live spots
BYE   # disconnect

Setting your grid and noise class takes ten seconds and makes the path hints meaningful for your station. Without a grid, GoCluster can’t estimate your path.

How do I use the web console?

Open ui.n2wq.com in a modern browser and log in with your callsign, plus the SSID your logger uses if it has one. The console shows live spots, a band map, history searches and your settings, and its Filters panel builds GO rules by clicking: Show rules are PASS rules and Hide rules are REJECT rules. It runs over HTTPS, so it usually works where port 8300 is blocked.

New to the console? The web console guide walks through every screen with pictures.

  • Same login, same filters. Filters and settings belong to the callsign and SSID. One telnet connection and one browser can use the same SSID at once and share them, so a rule you apply in the console also changes what your logger receives.
  • GO dialect. While a browser is connected, that login uses GO rules. Your saved CC filters are kept.
  • Try it first. The Filter Lab runs the same filter builder on sample spots, with no login.

How do I connect my logging program?

GoCluster sends the standard 76-character DX spot line, so any logger that reads DX Spider or AR-Cluster spots reads GoCluster spots too. Step-by-step guides:

Logger32, N3FJP and other programs: open the program’s DX cluster or telnet window, add a new host with address cluster.n2wq.com and port 8300, and log in with your callsign.

CC User and other CC11-aware clients: connect as usual, then type SET/VE7CC to switch your session to native CC11 spot output (UNSET/VE7CC switches back). It starts off on every connection. GoCluster’s documentation notes that full CC User interoperability is not yet qualified. Details.

What should I do in my first five minutes?

  1. Say where you are: SET GRID and SET NOISE.
  2. Pick bands in one word: PASS RULE 0 BAND=HFCONTEST AND MODE=CW.
  3. Check it: SHOW FILTER RULE, then RESUME.
  4. Save it: SAVE PRESET CONTEST; later, LOAD PRESET CONTEST.
  5. Read the tags: a C after the grid means GoCluster corrected a busted call. See the symbol guide.

Why am I not seeing spots?

SymptomWhat to check
Live spots stopped after a commandSHOW HOLD, then RESUME. Readbacks pause live spots on purpose.
No spots, or fewer than expectedSHOW FILTER and SHOW SETTINGS, then RESUME. Check band, mode, source, location and path or confidence rules.
A NEARBY rule never matchesCheck your saved grid. Missing proximity counts as false.
Repeated reports are missingSHOW DEDUPE; try SET DEDUPE FAST for more repeats.
Blank path symbolSet your grid. Blank means not enough evidence, not a closed band.
Comments look like codesSET DIAG OFF restores normal comments.
Settings differ after reconnectingCheck the full login callsign, including any SSID.
No FT8 or FT4 spotsNew logins leave them out. PASS RULE 1 MODE=FT8,FT4 adds them, or select FT8 and FT4 in the web console’s Filters.
Your logger keeps disconnecting with Another login with your callTwo telnet programs use the same callsign and SSID. Give each its own SSID. A browser and one telnet program can share a login.
The web console and your logger show different filtersThey are logged in with different callsigns or SSIDs. Type SHOW SETTINGS in the logger; the User line is the login to type in the console.

Connection questions

All 32 answers are in the FAQ. New to clusters? Read what a DX cluster is.

Watch live spots in 15 seconds.